Special Offer: Discounts of 7%, 10%, 12.5% and 15% are available when you order 10, 25, 50 and 100 items or more of this product.
- 4 x 3-wire or 4-wire PT100 thermometer Inputs
- Measuring range -200° to +800°C
- Converter resolution 22 bits
- Interface: USB 2.0 and Wi-Fi
- Built-in Web-server showing data in tabular and chart display formats
- Configurable alarms on each channel
- emails sent on alarm
- Internal Logger Memory: 256Kb
- Configurable log rate from 5 seconds to 24 hours
- Data download in CSV or Log formats
- Input connectors: 2mm Screw terminals
- Supply 5VDC @ 100m (PSU included)
- Operating Temperature range 0 ºC to 70 ºC operating
- Dimensions 92mm x 51mm x 18.3mm
The PT-04 is a four channel PT100 thermometer input data-logger. It offers high resolution, high accuracy readings and is compatible with a wide range of PT100 sensors. Converters have Wi-Fi and USB interfaces, which is ideal for remote monitoring applications. Units incorporate a built-in web-server and require no PC application software to function; all units include 256Kb of internal memory for stand-alone operation.
Input channels
Input channels can be assigned meaningful names, have scaling applied so data can be shown in engineering units. The channel status is indicated by the symbol next to a corresponding channel. There is also a status indicator on the homepage to alert you to any problems.
These indicators show:
- Green - Channel is healthy.
- Yellow - Channel is currently healthy but has at some point been operating outside of its limit.
- Red - Channel is current operating outside of its limit – if this condition persists permanent damage may occur.
The graphical interface allows the data to be displayed in various graphical formats and can be easily controlled by the toolbar below the trace.
Data logging
Data can be stored in internal memory for recall and download at a later date. The Download button shows the download data page and allows you to retrieve saved data (in .csv format). You can also clear recorded data.
The Samples Tab allows you to set which channels are logged, the log rate from 5 seconds to 24 hours and what happens when the memory becomes full - either logging stops, or new data overwrites old data. The estimated total logging time is also displayed.
Alarms
Each input can be assigned a high or low alarm threshold. An email alert can be sent when the alarm threshold is exceeded. It is also possible to configure so the iDAQ sends a daily or weekly summary email.
Console Interface
The unit can be fully configured using the console interface provided by the USB 2.0 port. To access this interface the user will need to start a third party terminal application (such as MicrosoftTM Hyperterminal) and connect to the iDAQ emulated COM port.
Downloads
Quick Start Guide >>
User Manual >>
USB driver and Tools >>